This installation manual concerns the VRV IV, full inverter driven, heat pump system. Model line up: Model Description RXYTQ816Single non-continuous heating model. RXYTQ1848Multi non-continuous heating model (consisting of 2 or 3 RXYTQ modules). These units are intended for outdoor installation and aimed for heat pump air to air applications. Introduction the original VRV air conditioning system to Europe, invented by Daikin in 1982 › Up to 6 indoor units connected to 1 outdoor unit 1991 Introduce VRV heat recovery › Simultaneous cooling and heating 1994 Awarded ISO9001 certification 2004 Expand to light commercial sector with VRVII-S › Available in 4, 5, 6HP capacities.
- Vrv Air Conditioning Systems Pdf Download
- Mitsubishi Vrv Air Conditioning
- What Is Vrv System In Hvac
- Daikin Vrv Air Conditioning System Pdf
What’s the difference between VRV and VRF?
Many people mistakenly believe that VRV and VRF are two different HVAC technologies. Actually, VRV and VRF are two different terms for the same HVAC technology. Based on Inverter technology compressors, the first VRV HVAC systems were invented by Daikin during the early 1980’s.
As a technology leader in the HVAC industry, Daikin registered the VRV term (which stands for Variable Refrigerant Volume1) as an official trademark. All other companies use VRF (Variable Refrigerant Flow2) for their similar HVAC systems. Eventually, VRF became the more common term for these types of systems. This is the term that will be used for the rest of this article.
Want to proactively and intelligently diagnose, service and control your VRF HVAC?
Check out our solutions for HVAC service providers and professionals: Check out our simple solutions.
So what is VRF HVAC?
Think of VRF as the “Rolls-Royce” of Air Conditioning Systems. It’s a very sophisticated technological air conditioning system, based on several principles:
- Refrigerant only – where refrigerant is the only coolant material in the system (in contrary to the chilled water systems, where refrigerant is used for cooling/heating the water that is circulated throughout the whole system)
- Inverter compressors that allow lowering power consumption with partial cooling/heating loads
- Several air handlers (indoor units) on the same refrigerant loop/circuit
- Ability of modular expansion (especially applicable for large projects, that can grow in stages)
Typical VRF system structure
A typical system consists of an outdoor unit (comprising one or multiple compressors), several indoor units (often mistakenly called “fan coils”), refrigerant piping running from the outdoor to the indoors, using Refnet Joints (copper distributors in pipes) and communication wiring.
Communication wiring comprises a 2 wired cable chained from the outdoor to all indoors, creating an internal closed loop network. This is an essential part of any VRF installation.
As for the Control, each indoor is controlled by its own wired control panel, while there are some possibilities for wireless remotes (IR) and centralized controllers, enabling controlling all indoors from one location.
How does VRF HVAC work?
The operation logic of the VRF is fully built-in inside the system and is proprietary for each VRF manufacturer. The system gets inputs from the user (e.g. desired comfort temperature) and from the surroundings (outside ambient temperature). According to that data, it implements its logic in order to get to the desired comfort conditions, utilizing optimal power consumptions.
The ability to adjust itself to the outdoor conditions is one of the main factors that makes these systems so efficient, compared to the traditional water cooled systems, based on chillers and fan coils.
Now, let’s dive in, and see how it works in detail.
Let’s take as an example a typical VRF installation, with one outdoor unit and multiple indoors.
A Typical Example
At the beginning, the system is in standstill condition (everything is turned off).
Once a user turns one of the indoors “ON” by its local remote, the outdoor “gets noted” regarding it, and starts working. At this point, it will examine the outdoor conditions (temperature), the operating indoor requirements (operation mode, set point temperature), and will operate the compressor at the exact level, required to comply with the indoor requirements.
When another indoor unit is turned on, the outdoor recalculates the requirements from all the indoors, and will increase the compressor’s output, according to the required level of demand.
This process is constantly occurring with any change, performed in the HVAC system. As described, this system is fully automatic, and regulates its power consumption based on the demand arriving from the indoor units and outside prevailing conditions.
Users can have influence on the desired indoor comfort conditions, modifying: Operation mode (On/Off), Operation state (Cool/Heat/Fan/Dry/Auto), setpoint temperature, and fan speed (High/Medium/Low/Auto). Controlling those parameters is the only thing required for proper operation, and the only thing that is required for proper integration with the VRF system.
VRF HVAC System types
Cooling Only systems (less popular) – those systems can only cool. Heating is not available. Fan and Dry modes are available for each indoor unit independently.
Heat Pump systems (most popular) – all the indoor units can either heat, or cool (not at the same time). Fan and Dry modes are available for each indoor unit independently.
Heat Recovery systems (less popular) – those systems are the most sophisticated ones, where cooling and heating may be available by each indoor unit, independently, at the same time.
Footnotes
Want to proactively and intelligently diagnose, service and control your VRF HVAC?
Check out our solutions for HVAC service providers and professionals
Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982.[1] Like ductless minisplits, VRFs use refrigerant as the cooling and heating medium. This refrigerant is conditioned by one or more condensing units (which may be outdoors or indoors, water or air cooled), and is circulated within the building to multiple indoor units.[2] VRF systems, unlike conventional chiller-based systems, allow for varying degrees of cooling in more specific areas (because there are no large air handlers, only smaller indoor units), may supply hot water in a heat recovery configuration without affecting efficiency,[3] and switch to heating mode (heat pump) during winter without additional equipment, all of which may allow for reduced energy consumption. Also, air handlers and large ducts are not used which can reduce the height above a dropped ceiling as well as structural impact as VRF uses smaller penetrations for refrigerant pipes instead of ducts.[4]
Vrv Air Conditioning Systems Pdf Download
Description[edit]
VRFs are typically installed with an air conditioner inverter which adds a DC inverter to the compressor in order to support variable motor speed and thus variable refrigerant flow rather than simply perform on/off operation. By operating at varying speeds, VRF units work only at the needed rate allowing for substantial energy savings at load conditions. Heat recovery VRF technology allows individual indoor units to heat or cool as required, while the compressor load benefits from the internal heat recovery. Energy savings of up to 55% are predicted over comparable unitary equipment.[1][5] This also results in greater control of the building's interior temperature by the building's occupants.
VRFs come in two system formats, two pipe and three pipe systems. In a heat pump two pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others; this is usually done through a three pipe design, with the exception of Mitsubishi, Carrier and LG whose systems are able to do this with a two pipe system using a branch circuit (BC) controller to the individual indoor evaporator zones. In this case the heat extracted from zones requiring cooling is put to use in the zones requiring heating. This is made possible because the heating unit is functioning as a condenser, providing sub-cooled liquid back into the line that is being used for cooling. While the heat recovery system has a greater initial cost, it allows for better zoned thermal control of a building and overall greater efficiencies.[6] In heat recovery VRF systems, some of the indoor units may be in cooling mode while others are in heating mode, reducing energy consumption. If the coefficient of performance in cooling mode of a system is 3, and the coefficient of performance in heating mode is 4, then heat recovery performance can reach more than 7. While it is unlikely that this balance of cooling and heating demand will happen often throughout the year, energy efficiency can be greatly improved when the scenario occurs.[7]
VRF systems may be air or water cooled. If air cooled, VRF condensing units are exposed to outside air and may be outdoors, and condensing units are the size of large refrigerators, since they need to contain a large condenser (heat exchanger) which has a large surface area to transfer heat to the surrounding air, because air doesn't have a high heat capacity[8] and has a low density, volumetric thermal capacity and thermal conductivity thus needing to transfer heat into a large amount of air volume at once. If water cooled, the condensing units are placed indoors and are much smaller and cooled with water by a closed type or circuit cooling tower or dry cooler.
Japan[edit]
VRF systems have been used in Japan since the 1980s. By 2007, in Japan, VRFs are used in 50% of midsize office buildings (up to 70,000 ft2 or 6,500 m2) and 33% of large commercial buildings (more than 70,000 ft2 or 6,500 m2).[6] Daikin, a Japanese company, is the inventor of variable refrigerant volume systems (or VRV by Daikin air conditioning, other manufacturers remarketed this as VRF as VRV is a trademark).
Home automation integration[edit]
There are dedicated gateways that connect VRFs with home automation and building management systems (BMS) controllers for centralized control and monitoring. In addition, such gateway solutions are capable of providing remote control operation of all HVAC indoor units over the internet incorporating a simple and friendly user interface.[9][10]
Primary manufacturers[edit]
Japan:
- Fujitsu (Fujitsu General)
- Hitachi (Now Johnson Controls-Hitachi (Air Conditioning) (Jci-Hitachi)
- Yanmar (gas heat pumps)
- Sharp(former)
- Sanyo(now Panasonic)
- Toshiba Carrier(Former Air-conditioning & Heating International (AHI)(AHI-Carrier/Toshiba) (Toshiba-Carrier)[11][12] (As of 2018, the joint venture(s) seem to have been broken up, as Carrier now manufactures VRF systems of its own and Toshiba's websites no longer show the Carrier logo in their product images (which is not the case in some of Carrier's images[13][14]) and web pages, and the AHI-Carrier(Toshiba) website has not been updated since 2016)
Korea:
Mitsubishi Vrv Air Conditioning
India:
Italy:
What Is Vrv System In Hvac
United States:
- York International(Made by Hitachi)
- Trane (formerly made by Samsung, now made by Mitsubishi Electric)
- Afka Group (American Pro)
- CIAC(Carrier)
France:
China/Other:
Daikin Vrv Air Conditioning System Pdf
- Bosch (made by Midea[15][16])[17]
References[edit]
- ^ abThornton, Brian (December 2012). Variable Refrigerant Flow Systems(pdf). General Services Administration (Report). US Federal Government. Retrieved 2013-08-06.
- ^'VRF – 'Reason to choose VRF HVAC Technology' – 22-7 Website'. Retrieved 2019-09-05.
- ^https://oaktrust.library.tamu.edu/bitstream/handle/1969.1/5243/ESL-IC-06-11-104.pdf?sequence=4&isAllowed=y
- ^https://www.buildings.com/articles/28170/emergence-vrf-viable-hvac-option
- ^'Variable Refrigerant Flow'.
- ^ abGoetzler (April 2007). 'Variable Refrigerant Flow Systems'. ASHRAE Journal: 24–31.
- ^Rostamabadi, Mehrdad (2017). VRF HVAC Systems. Shafaf.
- ^GF. Hundy, A.R. Trott, T.C. Welch,Chapter 6 - Condensers and Cooling Towers,Editor(s): G.F. Hundy, A.R. Trott, T.C. Welch,Refrigeration, Air Conditioning and Heat Pumps (Fifth Edition),Butterworth-Heinemann,2016,Pages 99-120,ISBN 9780081006474,https://doi.org/10.1016/B978-0-08-100647-4.00006-1
- ^'Cool Automation's CoolMasterNet Features IP Connectivity, Multi-Brand HVAC Support'. CE Pro. Retrieved 16 November 2015.
- ^'Air Condition Repair'. Tuesday, 10 August 2021
- ^'Toshiba Carrier Global | Air conditioner for residential, commercial and industrial uses'. www.toshiba-carrier.co.jp.
- ^'AHI Carrier Contacts'. www.ahi-toshiba.com.
- ^'Toshiba Carrier Ductless Heat Pump System - RAS-LAV/LKV | Carrier - Home Comfort'. Carrier.
- ^'Toshiba Carrier Variable Refrigerant Flow Systems | Carrier Commercial Systems North America'. Carrier.
- ^'VRF: Bosch Enters the Market'. ACR Journal.
- ^'Bosch enters VRF joint venture with Midea'. Cooling Post. April 1, 2015.
- ^'VRF systems | Products |'. Buderus.